Pulmonary veins isolation with non-irrigated ablation catheters

  • A. Doronin Ukrainian National Medical Postgraduate Academy (Kyiv)
  • Y. Suslina Ukrainian Children’s Cardiac Center (Kyiv)
  • A. Riznyk Ukrainian Children’s Cardiac Center (Kyiv)
  • V. Khanenova Ukrainian Children’s Cardiac Center (Kyiv)
  • Y. Marushko Ukrainian Children’s Cardiac Center (Kyiv)
  • M. Meshkova Ukrainian Children’s Cardiac Center (Kyiv)
Keywords: atrial fibrillation, pulmonary veins isolation, efficiency

Abstract

The article analyzes our own experience of the pulmonary veins isolation during radiofrequency catheter ablation of atrial fibrillation (AF) with 4 mm tip non-irrigated catheters. The results of 145 primary AF catheter ablations in consecutive patients with paroxysmal AF have been analyzed. During the procedure after each 15–20 applications the ablation catheter was removed and wiped with a damp cloth.

The average time of X-ray exposure was 25.2±6.3 min. The recurrence of AF in 1 year after ablation occurred in 43 (29.7%) patients, another 1 (0.7%) had a typical atrial flutter, 1 – atrial tachycardia, 1 – left atrial flutter. Sinus rhythm has been preserved without the use of antiarrhythmic drugs during the 1 year after procedure in 99 (68.3%) patients.

There were 4 (2.8%) complications: 2 (1.4%) cases of pericardial tamponade treated with pericardiocentesis and 2 (1.4%) cases of pericardial effusion, which were treated conservatively. Thus, this technique is quite effective and safe.

References

1. Updated world wide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation / Cappato R., Calkins H., ChenS. A. et al. // Circ. Arrhythm. Electrophysiol. – 2010. – Vol. 3. – P. 32–38.

2. HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation / Calkins H., Hindricks G., Cappato R. et al. // Heart Rhythm. – 2017. – Vol. 14. – P. 275–444.

3. Electrophysiological endpoint for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci / Haissaguerre M. et al. // Circulation. – 2000. – Vol. 101 (12). – P. 1409–1417.

4. Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation / Pappone C. et al. // Circulation. – 2000. – Vol. 102 (21). – P. 2619–2628.

5. Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study / Arentz T. et al. // Circulation. – 2007. – Vol. 115 (24). – P. 3057–3063.

6. Buch E., Shivkumar K. Catheter Ablation of Atrial Fibrillation Advent of Second-Generation Technologies // Journal of the American college of cardiology. – 2015. – Vol. 66. – № 12.– P. 1361–1363.

7. Ghosh J. M., Mcguire M. A. The Full Circle: Back into the Pulmonary Veins: A New Possibility in AF Ablation? // J Cardiovasc Electrophysiol. – September 2015. – Vol. 26. – P. 1007–1008.

8. Pulmonary vein Re-isolation as a routine strategy / Dass M. et al. – UK, Cardiostim, 2016.
Published