Long-term results of fallot tetralogy total correction with the use of combined pulmonary valve biological prostheses (case report)

  • M. F. Zinkovskyi National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • A. G. Goryachev National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • V. І. Kravchenko National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • S. О. Dykuha National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • M. Yu. Atamanyuk National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • О. Karimov National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • V. N. Hrapunov National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
  • K. B. Babadzanov National M. M. Amosov Institute of Cardiovascular Surgery National Academy of Medical Sciences of Ukraine
Keywords: Fallot tetralogy, total correction, bioprosthesis, long-term results

Abstract

Long-term survival with good clinical and hemodynamic results is shown on the example of 3 cases of Fallot tetralogy total correction with the use of personally made xenoaortic bioprostheses in the pulmonary artery position (terms of observation: 38, 37, 20 years).

References

1. Lillehei C., Cohen M., Warden H., Varco P. Complete anatomical correction of tetralogy of Fallot defect: report of a successful surgical case // Arch. Surg. – 1956. – Vol. 73. – P. 526.

2. Marchand P. The use of a cusp bearing homograft patch to the outflow tract and pulmonary artery in Fallot’s tetralogy and pulmonary valvular stenosis // Thorax. – 1967. – Vol. 22. – P. 497.

3. Trusler G., Igengar S. Reconstruction of the pulmonary valve and outflow tract // J.T.C.V.S. – 1973. – Vol. 15, N 2. – P. 245.

4. Senage T., Tourneau T. L., Foucher Y., et. al. Early structural valve deterioration of mitroflow aortic bioprosthesis: mode, incidence and impact on outcome in a large cohort of patients // Circulation. – 2014. – Vol. 130. – P. 2012–2020.

5. Grunkemeier G. L., Furnary A. P., Wu Y. X., et al. Durability of pericardial versus porcine bioprosthetic heart valves // J.T.C.V.S. – 2012. – Vol. 144. – P. 1381–1386.

6. Ius F., Basso C., Deiia Barbera M., et al. CryoLife O’Brien aortic stentiess reoperations: clinical results and morphologic results // Eur. J.C-T.S. – 2013. – Vol. 43. – P. 729–736.

7. Knowles R., Veldtman G., Hickey E. Et al. Functional health status of adults with tetralogy of Fallot: matched comparison with healthy siblings // Ann. Thorac. Surg. – 2012. – Vol. 94. – P. 124–132.

8. Demyanchuk V. B., Dykukha S. O., Dovgan A. M., Lazorishinets V. V. Pseudoaneurysm of subclavian artery 21-years after staged repair of tetralogy of Fallot // Eur. J.C-T.S. – 2002. – Vol. 21. – P. 114–116.
Published
2016-09-12
How to Cite
Zinkovskyi, M. F., Goryachev, A. G., KravchenkoV. І., DykuhaS. О., Atamanyuk, M. Y., KarimovО., Hrapunov, V. N., & Babadzanov, K. B. (2016). Long-term results of fallot tetralogy total correction with the use of combined pulmonary valve biological prostheses (case report). Ukrainian Journal of Cardiovascular Surgery, (2 (25), 117-119. Retrieved from https://cvs.org.ua/index.php/ujcvs/article/view/252

Most read articles by the same author(s)