Evaluation of the Results of Left Bundle Branch Pacing after Atrioventricular Junction Ablation in Patients with Chronic Atrial Fibrillation
Abstract
Atrioventricular junction ablation (AVJA) together with the implantation of cardiac pacemaker has become a recognized and effective treatment strategy for patients with symptomatic tachysystolic atrial fibrillation that does not respond to heart rate control drug therapy. Left bundle branch pacing (LBBP) is a physiological alternative to right ventricular and biventricular pacing.
The aim. To analyze the clinical results of the average duration with the use of LBBP and AVJA.
Materials and methods. Over the period from January 2023 to July 2024, LBBP with subsequent AVJA was applied at the National Amosov Institute of Cardiovascular Surgery in 18 patients as a method of treatment of chronic tachysystolic atrial fibrillation to achieve heart rate control.
Results. Mid-term results (at least 1 month) could be monitored in 15 out of 18 patients (84%); in the other three (16%) patients the time between pacemaker implantation and AVJA was too short. The mean period from pacemaker implantation to control examination was 5.07 ± 2.79 months (minimum period 1 month, maximum 12 months). During the period from implantation and ablation to the control observation in the study group, it was possible to observe an increase in left ventricular ejection fraction from 39.12 ± 10.56% to 46.38 ± 7.09%, p = 0.035; decrease in the values of end-diastolic volume from 184.22 ± 76.76 to 167.85 ± 36.93 ml, p = 0.074; decrease in the right ventricular pressure from 43.07 ± 8.29 to 34.38 ± 4.78 mm Hg, p = 0.013. It was also possible to observe a decrease in the left bundle branch capture thresholds from 1.27 ± 0.58 to 0.7 ± 0.39 V at 0.4 ms, p = 0.016; and a decrease in the average LBBP endocardial lead resistance from 638 ± 172.83 to 529.4 ± 120.15 Ohm, p = 0.012.
Conclusions. Implantation of the LBBP pacemaker and AVJA was not associated with the occurrence of complications both in the intraoperative and postoperative periods, as well as in the remote period of the average duration in the studied group. The use of this approach in patients with chronic atrial fibrillation made it possible in a series of consecutive patients to improve the systolic function of the left ventricle, to reduce the values of the end-diastolic volume of the left ventricle and the right ventricular pressure at optimal pacing parameters.
References
- Joglar JA, Chung MK, Armbruster AL, Benjamin EJ, Chyou JY, Cronin EM, et al.; Peer Review Committee Members. 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2024;149(1):e1-e156. https://doi.org/10.1161/CIR.0000000000001193
- Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al.; ESC Scientific Document Group. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427-3520. https://doi.org/10.1093/eurheartj/ehab364
- Brignole M, Pentimalli F, Palmisano P, Landolina M, Quartieri F, Occhetta E, et al.; APAF-CRT Trial Investigators. AV junction ablation and cardiac resynchronization for patients with permanent atrial fibrillation and narrow QRS: the APAF-CRT mortality trial. Eur Heart J. 2021;42(46):4731-4739. https://doi.org/10.1093/eurheartj/ehab569
- Jastrzebski M, Dandamudi G, Burri H, Ellenbogen KA. Conduction system pacing: overview, definitions, and nomenclature. Eur Heart J Suppl. 2023;25(Suppl G):G4-G14. https://doi.org/10.1093/eurheartjsupp/suad114
- Vijayaraman P, Chelu MG, Curila K, Dandamudi G, Herweg B, Mori S, et al. Cardiac Conduction System Pacing: A Comprehensive Update. JACC Clin Electrophysiol. 2023;9(11):2358-2387. https://doi.org/10.1016/j.jacep.2023.06.005
- Keene D, Anselme F, Burri H, Pérez ÓC, Čurila K, Derndorfer M, et al. Conduction system pacing, a European survey: insights from clinical practice. Europace. 2023;25(5):euad019. https://doi.org/10.1093/europace/euad019
- Kircanski B, Boveda S, Prinzen F, Sorgente A, Anic A, Conte G, et al. Conduction system pacing in everyday clinical practice: EHRA physician survey. Europace. 2023;25(2):682-687. https://doi.org/10.1093/europace/euac201
- Pillai A, Kolominsky J, Koneru JN, Kron J, Shepard RK, Kalahasty G, et al. Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads. Heart Rhythm. 2022;19(7):1116-1123. https://doi.org/10.1016/j.hrthm.2022.03.1222
- Su L, Cai M, Wu S, Wang S, Xu T, Vijayaraman P, et al. Long-term performance and risk factors analysis after permanent His-bundle pacing and atrioventricular node ablation in patients with atrial fibrillation and heart failure. Europace. 2020;22(Suppl_2):ii19-ii26. https://doi.org/10.1093/europace/euaa306
- Vijayaraman P, Subzposh FA, Naperkowski A. Atrioventricular node ablation and His bundle pacing. Europace. 2017;19(suppl_4):iv10-iv16. https://doi.org/10.1093/europace/eux263
- Zhuo W, Zhong X, Liu H, Yu J, Chen Q, Hu J, et al. Pacing Characteristics of His Bundle Pacing vs. Left Bundle Branch Pacing: A Systematic Review and Meta-Analysis. Front Cardiovasc Med. 2022;9:849143. https://doi.org/10.3389/fcvm.2022.849143
- Liu Z, Liu X. Feasibility and Safety Study of Concomitant Left Bundle Branch Area Pacing and Atrioventricular Node Ablation with Same-Day Hospital Dismissal. J Clin Med. 2023;12(22):7002. https://doi.org/10.3390/jcm12227002
- Rijks JHJ, Lankveld T, Manusama R, Broers B, Stipdonk AMWV, Chaldoupi SM, et al. Left Bundle Branch Area Pacing and Atrioventricular Node Ablation in a Single-Procedure Approach for Elderly Patients with Symptomatic Atrial Fibrillation. J Clin Med. 2023;12(12):4028. https://doi.org/10.3390/jcm12124028
- Palmisano P, Ziacchi M, Dell’Era G, Donateo P, Bartoli L, Patti G, et al. “Ablate and Pace” with Conduction System Pacing: Concomitant versus Delayed Atrioventricular Junction Ablation. J Clin Med. 2024;13(8):2157. https://doi.org/10.3390/jcm13082157
- Li Q, Dai W, Fang D, Ma W, Lin C, Lu C, et al. Occurrence of ventricular septal perforation in patients with permanent left bundle branch pacing followed up using echocardiographic and computed tomography images. Ann Noninvasive Electrocardiol. 2022 Nov;27(6):e13002. https://doi.org/10.1111/anec.13002
- Ravi V, Larsen T, Ooms S, Trohman R, Sharma PS. Late-onset interventricular septal perforation from left bundle branch pacing. HeartRhythm Case Rep. 2020;6(9):627-631. https://doi.org/10.1016/j.hrcr.2020.06.008
- Ponnusamy SS, Basil W, Vijayaraman P. Electrophysiological characteristics of septal perforation during left bundle branch pacing. Heart Rhythm. 2022;19(5):728-734. https://doi.org/10.1016/j.hrthm.2022.01.018
- Baranchuk A, Glover BM, Ho SY, Sanchez-Quintana D, Brugada P. Cardiac Anatomy and Electrophysiology. In: Glover BM, Brugada P, editors. Clinical Handbook of Cardiac Electrophysiology. 2nd ed. Springer, Cham;2021. p. 1-29. https://doi.org/10.1007/978-3-030-74319-2_1
- Huang W, Chen X, Su L, Wu S, Xia X, Vijayaraman P. A beginner’s guide to permanent left bundle branch pacing. Heart Rhythm. 2019;16(12):1791-1796. https://doi.org/10.1016/j.hrthm.2019.06.016
- Jastrzębski M, Burri H, Kiełbasa G, Curila K, Moskal P, Bednarek A, et al. The V6-V1 interpeak interval: a novel criterion for the diagnosis of left bundle branch capture. Europace. 2022;24(1):40-47. https://doi.org/10.1093/europace/euab164.