Morphological changes in the iliac artery walls of pigs after implantation of spiral devices from β-zirconium alloy
Keywords:
patent ductus arteriosus, a heart occluder, the biological model, β-zirconium alloy
Abstract
The results of histological studies of the iliac arteries of pigs wall after the implantation of the spiral device – occluder, made on the basis of low modulus β-zirconium alloy. It is shown that in 2.5 months after the introduction into the lumen of the artery of the occluder, a capsule is formed around of neointimal fibrosis, which overlaps occluder more than 2/3 of the lumen of the vessel, indicating a good device occlusive effect.
References
1. Porstmann W., Wierny L., Warnke H. Catheter closure of patent ductus arteriosus: 62 cases treated without thoracotomy // Radiol Clin North Am. – 1971. – Vol. 9. – Р. 203–218.
2. Celiker A., Aypar E., Karagoz T., Dilber E., Ceviz N. Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils // Catheter Cardiovasc Interv. – 2005. – Vol. 65. – Р. 569–76.
3. Gruenstein D. H., Bass J. L. Experimental evaluation of a new articulated Amplatzer ductal occlude device without fabric // Catheter Cardiovascular Interventional. – 2009. – Vol. 74. – Р. 482–487.
4. Ryhanen J., Niemi E., Serlo W., Niemela E., Sandvik P., Pernu H., et al. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures // J Biomed Mater Res. – 1997. – Vol. 35. – Р. 451–457.
5. Niinomi M. Mechanical biocompatibilities of titanium alloys for biomedical applications // Journal of the Mechanical Behavior of Biomedical Materials. – 2000. – Vol. 1. – P. 30–42.
6. Trepanier C., Venugopalan R., Messer R. Z. J., Pelton A. R. Effect of Passivation treatments on nickel release from nitinol // Society for Biomateria. – 6th World Biomaterials Congress, Transactions. – 2000. – Р. 1043.
7. Burian M., Neumann T., Weber M., Brandt R., Geisslinger G., Mitrovic V., et al. Nickel release, a possible indicator for the duration of antiplatelet treatment, from a nickel cardiac device in vivo: a study in patients with atrial septal defects implanted with an Amplatzer occlude // Int J. Clin.Pharmacol Ther. – 2006. – Vol. 44. – Р. 107–112.
8. Sigler M., Jux C. Biocompatibility of septal defect closure devices // Heart. – 2007. – Vol. 9. – Р. 444–449.
9. Скиба И. А., Карасевская О. П., Мордюк Б. Н., Марковский П. Е., Шиванюк В. Н. Влияние инициируемого деформацией ?>?превращения на механическое поведение β-сплавов титана и циркония // Металлофизика и новейшие технологии. – Т. 31. – № 1. – 2009. – С. 1573–1586.
10. Кулеш Д. В., Скиба И. О., Карасевская О. П. и др. Микроструктура, механические свойства и биосовместимость нового Zr-Ti-Nb сплава // Пластична та реконструктивна хірургія. – 2011. – № 2 (XVII). – С. 44–50.
11. Паничкин Ю. В., Скиба И. А., Захарова В. П. и др. Особенности методики проведения доклинического эксперимента по имплантации окклюдера из β-циркониевого сплава на свиньях как биологической модели // Серце і судини. – 2015. – № 4 (52). – С. 25–30.
2. Celiker A., Aypar E., Karagoz T., Dilber E., Ceviz N. Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils // Catheter Cardiovasc Interv. – 2005. – Vol. 65. – Р. 569–76.
3. Gruenstein D. H., Bass J. L. Experimental evaluation of a new articulated Amplatzer ductal occlude device without fabric // Catheter Cardiovascular Interventional. – 2009. – Vol. 74. – Р. 482–487.
4. Ryhanen J., Niemi E., Serlo W., Niemela E., Sandvik P., Pernu H., et al. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures // J Biomed Mater Res. – 1997. – Vol. 35. – Р. 451–457.
5. Niinomi M. Mechanical biocompatibilities of titanium alloys for biomedical applications // Journal of the Mechanical Behavior of Biomedical Materials. – 2000. – Vol. 1. – P. 30–42.
6. Trepanier C., Venugopalan R., Messer R. Z. J., Pelton A. R. Effect of Passivation treatments on nickel release from nitinol // Society for Biomateria. – 6th World Biomaterials Congress, Transactions. – 2000. – Р. 1043.
7. Burian M., Neumann T., Weber M., Brandt R., Geisslinger G., Mitrovic V., et al. Nickel release, a possible indicator for the duration of antiplatelet treatment, from a nickel cardiac device in vivo: a study in patients with atrial septal defects implanted with an Amplatzer occlude // Int J. Clin.Pharmacol Ther. – 2006. – Vol. 44. – Р. 107–112.
8. Sigler M., Jux C. Biocompatibility of septal defect closure devices // Heart. – 2007. – Vol. 9. – Р. 444–449.
9. Скиба И. А., Карасевская О. П., Мордюк Б. Н., Марковский П. Е., Шиванюк В. Н. Влияние инициируемого деформацией ?>?превращения на механическое поведение β-сплавов титана и циркония // Металлофизика и новейшие технологии. – Т. 31. – № 1. – 2009. – С. 1573–1586.
10. Кулеш Д. В., Скиба И. О., Карасевская О. П. и др. Микроструктура, механические свойства и биосовместимость нового Zr-Ti-Nb сплава // Пластична та реконструктивна хірургія. – 2011. – № 2 (XVII). – С. 44–50.
11. Паничкин Ю. В., Скиба И. А., Захарова В. П. и др. Особенности методики проведения доклинического эксперимента по имплантации окклюдера из β-циркониевого сплава на свиньях как биологической модели // Серце і судини. – 2015. – № 4 (52). – С. 25–30.
Published
2016-09-12
How to Cite
Zakharova, V. P., Panichkin, Y. V., Skiba, I. O., Zhuravleva, M. L., Beshlyaga, V. M., Beshlyaga, E. V., & Ruzhin, Y. A. (2016). Morphological changes in the iliac artery walls of pigs after implantation of spiral devices from β-zirconium alloy. Ukrainian Journal of Cardiovascular Surgery, (2 (25), 105-107. Retrieved from https://cvs.org.ua/index.php/ujcvs/article/view/248
Section
GENERAL ISSUES OF TREATMENT OF PATIENTS WITH CARDIOVASCULAR PATHOLOGY